Home >> Products >> Reagents >> SensiFAST™ cDNA Synthesis Kit

SensiFAST™ cDNA Synthesis Kit

SensiFAST™ cDNA Synthesis Kit, 250 reactions
  • Unique reverse transcriptase and new 5x TransAmp™ buffer generates consistent first-strand cDNA
  • Ideal for dilute and low-copy samples
  • Real-Time RT-PCR analysis from as little as 1pg of starting total RNA
  • Complete 5' to 3' RNA sequence representation
  • Optimized protocol produces cDNA in 15 minutes
CONTACT US
KONTAKTIERE UNS
KONTAKTIERE UNS
KONTAKTIERE UNS

SensiFAST™ cDNA Synthesis Kit – Fast, Accurate, and Reliable cDNA Synthesis for qPCR

The SensiFAST™ cDNA Synthesis Kit is a high-performance solution for fast and accurate synthesis of first-strand cDNA from RNA samples. It is designed for gene expression analysis, tissue biopsy studies, and RNA detection. With a novel TransAmp™ buffer system and an optimized blend of random hexamers and anchored oligo(dT) primers, this kit delivers high-quality cDNA ready for real-time qPCR in as little as 5 minutes.

Ideal for researchers working with low-copy or dilute RNA, this kit guarantees accurate detection and reliable results across a wide range of applications. Whether you are working with complex templates, inhibitors, or small sample volumes, the SensiFAST™ cDNA Synthesis Kit provides the speed, sensitivity, and versatility needed for successful cDNA synthesis.

Key Features of SensiFAST™ cDNA Synthesis Kit

  • Efficient Reverse Transcription: The high target affinity, coupled with the advanced TransAmp™ Buffer, improves the yield of full-length cDNA, providing reliable results.
  • Unbiased cDNA Synthesis: The optimized mix of random hexamers and anchored oligo(dT) primers ensures complete 5’ to 3’ RNA sequence coverage, crucial for precise gene expression analysis.
  • Sensitive and Accurate: Detect low-copy targets with lower Ct values from as little as 1 pg of RNA input, ensuring accurate detection even in dilute samples.
  • Robust Performance: Achieve consistent reverse transcription under challenging conditions, including complex RNA templates and inhibitors.
  • Fast Workflow: Complete high-yield reverse transcription in as little as 5 minutes, ensuring rapid results in real-time qPCR experiments.

Applications

The SensiFAST™ cDNA Synthesis Kit is ideal for a variety of molecular biology applications, including:

  • Gene Expression Analysis: Perfect for qPCR studies requiring accurate gene expression quantification from different RNA templates.
  • Tissue Biopsy Analysis: Great for reverse transcription from small, precious RNA samples, such as laser-microdissected tissues or biopsy samples.
  • miRNA Profiling & Quantification: Enables accurate reverse transcription for miRNA detection and quantification.
  • Pathogen Detection: Sensitive enough to detect viral and bacterial RNA, making it useful for clinical diagnostics and pathogen research.
  • RNA Target Detection: Ensures reliable detection of RNA targets, even in low-copy or challenging samples.

Why Choose SensiFAST™ cDNA Synthesis Kit?

  • High-Quality Reverse Transcription: Achieve high-fidelity cDNA synthesis for downstream applications like qPCR, sequencing, and cloning.
  • Broad Application Compatibility: Supports various RNA sample types, including total RNA from tissues, biopsies, and cell lines, making it versatile for different molecular biology needs.
  • Fast and Reliable: The ability to generate qPCR-ready cDNA in as little as 5 minutes allows you to proceed with your experiments quickly without compromising on quality.

For more advanced laboratory services and technical support, visit our Lab Service & Technical Support page to learn more about our solutions.

Technical Specifications

  • Reactions: 250 reactions per kit
  • Input RNA: As low as 1 pg of total RNA
  • Reaction Time: Complete reverse transcription in 5-15 minutes
  • Primer Mix: Random hexamers and anchored oligo(dT) primers for full RNA sequence representation
  • Buffer System: TransAmp™ buffer system for enhanced performance
  • RNA Compatibility: Suitable for a wide range of RNA sample types, including tissue biopsies and clinical samples

How It Works

  • Lysis and RNA Isolation: Isolate RNA from your samples, such as tissue biopsies, using methods like the NucleoSpin RNA Isolation Kit.
  • Reverse Transcription: Add your isolated RNA to the SensiFAST™ cDNA Synthesis Kit. The TransAmp™ buffer ensures optimal conditions for reverse transcription, and LyseControl helps you monitor the reaction visually.
  • cDNA Synthesis: In just 5-15 minutes, your RNA is reverse transcribed into high-quality cDNA, ready for use in downstream applications such as qPCR or miRNA profiling.
  • Real-Time PCR: Use your synthesized cDNA with SensiFAST Probe or SYBR Kits for fast and accurate real-time qPCR results.

To learn more about our range of lab solutions, check out our Lab Outsourcing Services, where we offer expert management of laboratory operations.

The SensiFAST cDNA Synthesis Kit has been developed to generate real-time ready first strand cDNA from total RNA templates.
The kit contains a unique TransAmp™ buffer system to deliever the highest quality cDNA.
A blend of random and oligo(dT) primers provide robust, consistent and unbiased first-strand synthesis over a broad range of RNA template concentrations, making SensiFast cDNA Synthesis Kit the ideal partner for SensiFAST Probe and SYBR real-time PCR kits.

Buy this product

Kaufen Sie dieses Produkt

Order this product in
LabShop online
Bestellen Sie dieses Produkt in
LabShop online
ORDER ONLINE ONLINE BESTELLEN
Reach out by phone Kontaktieren Sie uns telefonisch
Reach out by phone
+43 (01) 244 28 55
The LabShop team will be happy to advise you

The LabShop team will be happy to advise you

Das LabShop-Team berät Sie gerne

FREE CONSULTATION
FREE CONSULTATION
KOSTENLOSE BERATUNG
FREE CONSULTATION